Part Number Hot Search : 
SRC1204E BD8100S SY10EL51 F1005 EH72025 12003 TFS70Z WFA310
Product Description
Full Text Search
 

To Download TMP90 Datasheet File

  If you can't view the Datasheet, Please click here to try to view without PDF Reader .  
 
 


  Datasheet File OCR Text:
 TRUMPower
D E SCR IPTION
The TMP90 is a series of AC/DC desktop power adapters with 60 to 90 watts of continuous output power. They are enclosed in a 94V-1 rated case with an IEC 320/C14 or C18 inlet for medical and ITE applications. All models meet EN55011, EN55022 and FCC class B emission limits, and are designed for medical applications.
90 WATTS MEDICAL POWER ADAPTERS
TMP90 SERIES
( LV D )
RoHS
F EATU R E S
Low safety ground leakage current IEC320/C14 (Class I) or C18 (Class II) Inlet 9 0 t o 2 6 4 VA C w i d e i n p u t r a n g e Optional output connectors O v e r v o l ta g e & o v e r c u r r e n t p r o t e c t i o n s 0.98 PFC 100% burn-in C o m p l i a n t w i t h C E C a n d E n e r g y S ta r e f f i c i e n c y l e v e l I V r e q u i r e m e n ts ( e x c e p t 1 2 V o u t p u t m o d e l s ) No load power consumption less than 0.5W Av e r a g e a c t i v e e f f i c i e n c y 8 5 % C o m p l i a n t w i t h R o H S r e q u i r e m e n ts
Saf et y Sta n da rd A ppr o va ls
UL 60601-1 CSA C22.2 No. 601.1 TUV EN60601-1
IN PUT S PE C IF ICAT ION S
I n p u t v o l ta g e : Input frequency : Input current : Earth leakage current : 90 to 264VAC 47 to 63Hz 1.20A (rms) for 115VAC 0.60A (rms) for 230VAC 90A max. @ 115VAC, 60Hz 150A max. @ 230VAC, 50Hz
GENERAL SPECIFICATIONS
Switching frequency 50 KHz - 110 KHz Power factor 0.98 Typical Efficiency 85% min. (78% min. for TMP90-05, TMP90-06, TMP90-09 and TMP90-12) Hold-up time 15 msec minimum at 110VAC Line regulation 0.5% maximum at full load Inrush current 40 amps @ 115VAC or 60 amps @ 230VAC, @ 25C cold start Withstand voltage 4000VAC from input to output 1500VAC from input to ground 500VAC from output to ground MTBF 150,000 hours minimum at full load at 25C ambient, calculated per MIL-HDBK-217F EMC Performance (IEC60601-1-2: 2001) E N 5 5 0 11 : FCC: VCCI: EN61000-3-2: EN61000-3-3: EN61000-4-2: EN61000-4-3: EN61000-4-4: EN61000-4-5: EN61000-4-6: EN61000-4-8: E N 6 1 0 0 0 - 4 - 11 : Class B conducted, Class B radiated Class B conducted, Class B radiated Class B conducted, Class B radiated Harmonic distortion, Class A and D Line flicker ESD, 8KV air and 6KV contact Radiated immunity, 3V/m Fast transient/burst, 2KV Surge, 1KV diff, 2KV com. Conducted immunity, 3Vrms Magnetic field immunity, 3A/m Voltage dips, 30% reduction for 500ms, 60% reduction for 100ms and >95% reduction for 10ms
OUTPUT SPECIFICATIONS
Output voltage/current Total output power Ripple and noise Over voltage protection Over current protection Temperature coefficient Transient response See rating chart See rating chart 2% peak to peak maximum Set at 112-140% of its nominal output voltage Protected to short circuit conditions 0.04%/C maximum Maximum excursion of 4% or better on all models, recovering to 1% of final value within 500s after a 25% step load change
E N V IR O N M ENTA L SP E C IF ICATI O N S
Operating temperature Storage temperature Relative humidity Derating 0 C t o + 6 0 C - 4 0 C t o + 8 5 C 5% to 95% non-condensing Derate from 100% at +40C linearly to 50% at +60C
Tumbler Technologies + TRUMPower
3350 Scott Blvd., Bldg. 13, Santa Clara, California 95054, USA Phone: 408-988-6616 Fax: 408-988-6622 email: sales@trumpower.com Website: www.TRUMPower.com
MEDICAL GRADE
OUTPUT VOLTAGE/CURRENT RATING CHART
Output Product No. TMP90-05 TMP90-06 TMP90-09 TMP90-12 TMP90-13.5 TMP90-15 TMP90-18 TMP90-19 TMP90-24 TMP90-30 TMP90-48 Vnom. 5V 6V 9V 12V 13.5V 15V 18V 19V 24V 30V 48V Imin. 0A 0A 0A 0A 0A 0A 0A 0A 0A 0A 0A Imax. 12.0A 10.0A 7.78A 6.67A 6.3A 5.67A 5.0A 4.74A 3.75A 3.0A 1.87A
TMP90 SERIES
Tol. 5% 5% 5% 5% 5% 5% 5% 5% 5% 5% 5% Maximum Output Power 60W 60W 70W 80W 85W 85W 90W 90W 90W 90W 90W
NOTES: 1. Ripple and noise: Peak-to-peak with 20MHz bandwidth and 10F tantalum capacitor in parallel with a 0.1F ceramic capacitor at rated line voltage and load ranges. 2. To order a model with IEC320/C18 inlet with class II insulation, add suffix "C2" , e.g. TMP90-12-C2.
MECHANICAL SPECIFICATIONS
NOTES: 1. Dimensions show in inch [mm] 2. Tolerance 0.02 [0.5] maximum 3. Weight: 658 grams approx. 4. Standard output connector is a male 4-pin power DIN. Please contact TRUMPower for other connector options. 5. TMP90-05 and TMP90-06 output connectors are without lock.
PIN CHART
PIN Product No. TMP90-05 TMP90-09 TMP90-13.5 TMP90-18 TMP90-24 TMP90-48 TMP90-06 TMP90-12 TMP90-15 TMP90-19 TMP90-30 1 2 3 4 Shell
RETURN
OUTPUT +V
RETURN
OUTPUT +V
AC Ground
Tumbler Technologies + TRUMPower
3350 Scott Blvd., Bldg. 13, Santa Clara, California 95054, USA Phone: 408-988-6616 Fax: 408-988-6622 email: sales@trumpower.com Website: www.TRUMPower.com


▲Up To Search▲   

 
Price & Availability of TMP90

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X